Fixed MTP to work with TWRP

This commit is contained in:
awab228 2018-06-19 23:16:04 +02:00
commit f6dfaef42e
50820 changed files with 20846062 additions and 0 deletions

View file

@ -0,0 +1,24 @@
BMP085/BMP18x digital pressure sensors
Required properties:
- compatible: bosch,bmp085
Optional properties:
- chip-id: configurable chip id for non-default chip revisions
- temp-measurement-period: temperature measurement period (milliseconds)
- default-oversampling: default oversampling value to be used at startup,
value range is 0-3 with rising sensitivity.
- interrupt-parent: should be the phandle for the interrupt controller
- interrupts: interrupt mapping for IRQ
Example:
pressure@77 {
compatible = "bosch,bmp085";
reg = <0x77>;
chip-id = <10>;
temp-measurement-period = <100>;
default-oversampling = <2>;
interrupt-parent = <&gpio0>;
interrupts = <25 IRQ_TYPE_EDGE_RISING>;
};

After

Width:  |  Height:  |  Size: 701 B