Documentation/hwmon/asb100
Normal file
72
Documentation/hwmon/asb100
Normal file
|
@ -0,0 +1,72 @@
|
|||
Kernel driver asb100
|
||||
====================
|
||||
|
||||
Supported Chips:
|
||||
* Asus ASB100 and ASB100-A "Bach"
|
||||
Prefix: 'asb100'
|
||||
Addresses scanned: I2C 0x2d
|
||||
Datasheet: none released
|
||||
|
||||
Author: Mark M. Hoffman <mhoffman@lightlink.com>
|
||||
|
||||
Description
|
||||
-----------
|
||||
|
||||
This driver implements support for the Asus ASB100 and ASB100-A "Bach".
|
||||
These are custom ASICs available only on Asus mainboards. Asus refuses to
|
||||
supply a datasheet for these chips. Thanks go to many people who helped
|
||||
investigate their hardware, including:
|
||||
|
||||
Vitaly V. Bursov
|
||||
Alexander van Kaam (author of MBM for Windows)
|
||||
Bertrik Sikken
|
||||
|
||||
The ASB100 implements seven voltage sensors, three fan rotation speed
|
||||
sensors, four temperature sensors, VID lines and alarms. In addition to
|
||||
these, the ASB100-A also implements a single PWM controller for fans 2 and
|
||||
3 (i.e. one setting controls both.) If you have a plain ASB100, the PWM
|
||||
controller will simply not work (or maybe it will for you... it doesn't for
|
||||
me).
|
||||
|
||||
Temperatures are measured and reported in degrees Celsius.
|
||||
|
||||
Fan speeds are reported in RPM (rotations per minute). An alarm is
|
||||
triggered if the rotation speed has dropped below a programmable limit.
|
||||
|
||||
Voltage sensors (also known as IN sensors) report values in volts.
|
||||
|
||||
The VID lines encode the core voltage value: the voltage level your
|
||||
processor should work with. This is hardcoded by the mainboard and/or
|
||||
processor itself. It is a value in volts.
|
||||
|
||||
Alarms: (TODO question marks indicate may or may not work)
|
||||
|
||||
0x0001 => in0 (?)
|
||||
0x0002 => in1 (?)
|
||||
0x0004 => in2
|
||||
0x0008 => in3
|
||||
0x0010 => temp1 (1)
|
||||
0x0020 => temp2
|
||||
0x0040 => fan1
|
||||
0x0080 => fan2
|
||||
0x0100 => in4
|
||||
0x0200 => in5 (?) (2)
|
||||
0x0400 => in6 (?) (2)
|
||||
0x0800 => fan3
|
||||
0x1000 => chassis switch
|
||||
0x2000 => temp3
|
||||
|
||||
Alarm Notes:
|
||||
|
||||
(1) This alarm will only trigger if the hysteresis value is 127C.
|
||||
I.e. it behaves the same as w83781d.
|
||||
|
||||
(2) The min and max registers for these values appear to
|
||||
be read-only or otherwise stuck at 0x00.
|
||||
|
||||
TODO:
|
||||
* Experiment with fan divisors > 8.
|
||||
* Experiment with temp. sensor types.
|
||||
* Are there really 13 voltage inputs? Probably not...
|
||||
* Cleanups, no doubt...
|
||||
|