Kernel driver w1_therm
|
||||
====================
|
||||
|
||||
Supported chips:
|
||||
* Maxim ds18*20 based temperature sensors.
|
||||
* Maxim ds1825 based temperature sensors.
|
||||
|
||||
Author: Evgeniy Polyakov <johnpol@2ka.mipt.ru>
|
||||
|
||||
|
||||
Description
|
||||
-----------
|
||||
|
||||
w1_therm provides basic temperature conversion for ds18*20 devices.
|
||||
supported family codes:
|
||||
W1_THERM_DS18S20 0x10
|
||||
W1_THERM_DS1822 0x22
|
||||
W1_THERM_DS18B20 0x28
|
||||
W1_THERM_DS1825 0x3B
|
||||
|
||||
Support is provided through the sysfs w1_slave file. Each open and
|
||||
read sequence will initiate a temperature conversion then provide two
|
||||
lines of ASCII output. The first line contains the nine hex bytes
|
||||
read along with a calculated crc value and YES or NO if it matched.
|
||||
If the crc matched the returned values are retained. The second line
|
||||
displays the retained values along with a temperature in millidegrees
|
||||
Centigrade after t=.
|
||||
|
||||
Parasite powered devices are limited to one slave performing a
|
||||
temperature conversion at a time. If none of the devices are parasite
|
||||
powered it would be possible to convert all the devices at the same
|
||||
time and then go back to read individual sensors. That isn't
|
||||
currently supported. The driver also doesn't support reduced
|
||||
precision (which would also reduce the conversion time).
|
||||
|
||||
The module parameter strong_pullup can be set to 0 to disable the
|
||||
strong pullup, 1 to enable autodetection or 2 to force strong pullup.
|
||||
In case of autodetection, the driver will use the "READ POWER SUPPLY"
|
||||
command to check if there are pariste powered devices on the bus.
|
||||
If so, it will activate the master's strong pullup.
|
||||
In case the detection of parasite devices using this command fails
|
||||
(seems to be the case with some DS18S20) the strong pullup can
|
||||
be force-enabled.
|
||||
If the strong pullup is enabled, the master's strong pullup will be
|
||||
driven when the conversion is taking place, provided the master driver
|
||||
does support the strong pullup (or it falls back to a pullup
|
||||
resistor). The DS18b20 temperature sensor specification lists a
|
||||
maximum current draw of 1.5mA and that a 5k pullup resistor is not
|
||||
sufficient. The strong pullup is designed to provide the additional
|
||||
current required.
|