# Generic thermal sysfs drivers configuration
|
||||
#
|
||||
|
||||
menuconfig THERMAL
|
||||
tristate "Generic Thermal sysfs driver"
|
||||
help
|
||||
Generic Thermal Sysfs driver offers a generic mechanism for
|
||||
thermal management. Usually it's made up of one or more thermal
|
||||
zone and cooling device.
|
||||
Each thermal zone contains its own temperature, trip points,
|
||||
cooling devices.
|
||||
All platforms with ACPI thermal support can use this driver.
|
||||
If you want this support, you should say Y or M here.
|
||||
|
||||
if THERMAL
|
||||
|
||||
config THERMAL_HWMON
|
||||
bool
|
||||
prompt "Expose thermal sensors as hwmon device"
|
||||
depends on HWMON=y || HWMON=THERMAL
|
||||
default y
|
||||
help
|
||||
In case a sensor is registered with the thermal
|
||||
framework, this option will also register it
|
||||
as a hwmon. The sensor will then have the common
|
||||
hwmon sysfs interface.
|
||||
|
||||
Say 'Y' here if you want all thermal sensors to
|
||||
have hwmon sysfs interface too.
|
||||
|
||||
config THERMAL_OF
|
||||
bool
|
||||
prompt "APIs to parse thermal data out of device tree"
|
||||
depends on OF
|
||||
default y
|
||||
help
|
||||
This options provides helpers to add the support to
|
||||
read and parse thermal data definitions out of the
|
||||
device tree blob.
|
||||
|
||||
Say 'Y' here if you need to build thermal infrastructure
|
||||
based on device tree.
|
||||
|
||||
choice
|
||||
prompt "Default Thermal governor"
|
||||
default THERMAL_DEFAULT_GOV_STEP_WISE
|
||||
help
|
||||
This option sets which thermal governor shall be loaded at
|
||||
startup. If in doubt, select 'step_wise'.
|
||||
|
||||
config THERMAL_DEFAULT_GOV_STEP_WISE
|
||||
bool "step_wise"
|
||||
select THERMAL_GOV_STEP_WISE
|
||||
help
|
||||
Use the step_wise governor as default. This throttles the
|
||||
devices one step at a time.
|
||||
|
||||
config THERMAL_DEFAULT_GOV_FAIR_SHARE
|
||||
bool "fair_share"
|
||||
select THERMAL_GOV_FAIR_SHARE
|
||||
help
|
||||
Use the fair_share governor as default. This throttles the
|
||||
devices based on their 'contribution' to a zone. The
|
||||
contribution should be provided through platform data.
|
||||
|
||||
config THERMAL_DEFAULT_GOV_USER_SPACE
|
||||
bool "user_space"
|
||||
select THERMAL_GOV_USER_SPACE
|
||||
help
|
||||
Select this if you want to let the user space manage the
|
||||
platform thermals.
|
||||
|
||||
endchoice
|
||||
|
||||
config THERMAL_GOV_FAIR_SHARE
|
||||
bool "Fair-share thermal governor"
|
||||
help
|
||||
Enable this to manage platform thermals using fair-share governor.
|
||||
|
||||
config THERMAL_GOV_STEP_WISE
|
||||
bool "Step_wise thermal governor"
|
||||
help
|
||||
Enable this to manage platform thermals using a simple linear
|
||||
governor.
|
||||
|
||||
config THERMAL_GOV_BANG_BANG
|
||||
bool "Bang Bang thermal governor"
|
||||
default n
|
||||
help
|
||||
Enable this to manage platform thermals using bang bang governor.
|
||||
|
||||
Say 'Y' here if you want to use two point temperature regulation
|
||||
used for fans without throttling. Some fan drivers depend on this
|
||||
governor to be enabled (e.g. acerhdf).
|
||||
|
||||
config THERMAL_GOV_USER_SPACE
|
||||
bool "User_space thermal governor"
|
||||
help
|
||||
Enable this to let the user space manage the platform thermals.
|
||||
|
||||
config CPU_THERMAL
|
||||
bool "generic cpu cooling support"
|
||||
depends on CPU_FREQ
|
||||
depends on THERMAL_OF
|
||||
help
|
||||
This implements the generic cpu cooling mechanism through frequency
|
||||
reduction. An ACPI version of this already exists
|
||||
(drivers/acpi/processor_thermal.c).
|
||||
This will be useful for platforms using the generic thermal interface
|
||||
and not the ACPI interface.
|
||||
|
||||
If you want this support, you should say Y here.
|
||||
|
||||
config GPU_THERMAL
|
||||
bool "generic gpu cooling support"
|
||||
depends on THERMAL_OF
|
||||
help
|
||||
This implements the generic gpu cooling mechanism through frequency
|
||||
reduction. An ACPI version of this already exists
|
||||
(drivers/acpi/processor_thermal.c).
|
||||
This will be useful for platforms using the generic thermal interface
|
||||
and not the ACPI interface.
|
||||
|
||||
If you want this support, you should say Y here.
|
||||
|
||||
config ISP_THERMAL
|
||||
bool "generic isp cooling support"
|
||||
depends on THERMAL_OF
|
||||
help
|
||||
This implements the generic gpu cooling mechanism through frequency
|
||||
reduction. An ACPI version of this already exists
|
||||
(drivers/acpi/processor_thermal.c).
|
||||
This will be useful for platforms using the generic thermal interface
|
||||
and not the ACPI interface.
|
||||
|
||||
If you want this support, you should say Y here.
|
||||
|
||||
config THERMAL_EMULATION
|
||||
bool "Thermal emulation mode support"
|
||||
help
|
||||
Enable this option to make a emul_temp sysfs node in thermal zone
|
||||
directory to support temperature emulation. With emulation sysfs node,
|
||||
user can manually input temperature and test the different trip
|
||||
threshold behaviour for simulation purpose.
|
||||
|
||||
WARNING: Be careful while enabling this option on production systems,
|
||||
because userland can easily disable the thermal policy by simply
|
||||
flooding this sysfs node with low temperature values.
|
||||
|
||||
config IMX_THERMAL
|
||||
tristate "Temperature sensor driver for Freescale i.MX SoCs"
|
||||
depends on CPU_THERMAL
|
||||
depends on MFD_SYSCON
|
||||
depends on OF
|
||||
help
|
||||
Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
|
||||
It supports one critical trip point and one passive trip point. The
|
||||
cpufreq is used as the cooling device to throttle CPUs when the
|
||||
passive trip is crossed.
|
||||
|
||||
config SPEAR_THERMAL
|
||||
bool "SPEAr thermal sensor driver"
|
||||
depends on PLAT_SPEAR
|
||||
depends on OF
|
||||
help
|
||||
Enable this to plug the SPEAr thermal sensor driver into the Linux
|
||||
thermal framework.
|
||||
|
||||
config RCAR_THERMAL
|
||||
tristate "Renesas R-Car thermal driver"
|
||||
depends on ARCH_SHMOBILE || COMPILE_TEST
|
||||
depends on HAS_IOMEM
|
||||
help
|
||||
Enable this to plug the R-Car thermal sensor driver into the Linux
|
||||
thermal framework.
|
||||
|
||||
config KIRKWOOD_THERMAL
|
||||
tristate "Temperature sensor on Marvell Kirkwood SoCs"
|
||||
depends on MACH_KIRKWOOD
|
||||
depends on OF
|
||||
help
|
||||
Support for the Kirkwood thermal sensor driver into the Linux thermal
|
||||
framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
|
||||
|
||||
config EXYNOS_THERMAL
|
||||
tristate "Temperature sensor on Samsung EXYNOS"
|
||||
depends on (ARCH_EXYNOS4 || ARCH_EXYNOS5 || ARCH_EXYNOS7 || ARCH_EXYNOS8)
|
||||
depends on CPU_THERMAL
|
||||
help
|
||||
If you say yes here you get support for TMU (Thermal Management
|
||||
Unit) on SAMSUNG EXYNOS series of SoC.
|
||||
|
||||
config EXYNOS_SWTRIP
|
||||
bool "SW TRIP Feature on Samsung EXYNOS"
|
||||
depends on EXYNOS_THERMAL
|
||||
help
|
||||
Support for SWTRIP uevent on SAMSUNG EXYNOS series of SOC
|
||||
|
||||
config DOVE_THERMAL
|
||||
tristate "Temperature sensor on Marvell Dove SoCs"
|
||||
depends on ARCH_DOVE || MACH_DOVE
|
||||
depends on OF
|
||||
help
|
||||
Support for the Dove thermal sensor driver in the Linux thermal
|
||||
framework.
|
||||
|
||||
config DB8500_THERMAL
|
||||
bool "DB8500 thermal management"
|
||||
depends on ARCH_U8500
|
||||
default y
|
||||
help
|
||||
Adds DB8500 thermal management implementation according to the thermal
|
||||
management framework. A thermal zone with several trip points will be
|
||||
created. Cooling devices can be bound to the trip points to cool this
|
||||
thermal zone if trip points reached.
|
||||
|
||||
config ARMADA_THERMAL
|
||||
tristate "Armada 370/XP thermal management"
|
||||
depends on ARCH_MVEBU
|
||||
depends on OF
|
||||
help
|
||||
Enable this option if you want to have support for thermal management
|
||||
controller present in Armada 370 and Armada XP SoC.
|
||||
|
||||
config DB8500_CPUFREQ_COOLING
|
||||
tristate "DB8500 cpufreq cooling"
|
||||
depends on ARCH_U8500
|
||||
depends on CPU_THERMAL
|
||||
default y
|
||||
help
|
||||
Adds DB8500 cpufreq cooling devices, and these cooling devices can be
|
||||
bound to thermal zone trip points. When a trip point reached, the
|
||||
bound cpufreq cooling device turns active to set CPU frequency low to
|
||||
cool down the CPU.
|
||||
|
||||
config INTEL_POWERCLAMP
|
||||
tristate "Intel PowerClamp idle injection driver"
|
||||
depends on THERMAL
|
||||
depends on X86
|
||||
depends on CPU_SUP_INTEL
|
||||
help
|
||||
Enable this to enable Intel PowerClamp idle injection driver. This
|
||||
enforce idle time which results in more package C-state residency. The
|
||||
user interface is exposed via generic thermal framework.
|
||||
|
||||
config X86_PKG_TEMP_THERMAL
|
||||
tristate "X86 package temperature thermal driver"
|
||||
depends on X86_THERMAL_VECTOR
|
||||
select THERMAL_GOV_USER_SPACE
|
||||
default m
|
||||
help
|
||||
Enable this to register CPU digital sensor for package temperature as
|
||||
thermal zone. Each package will have its own thermal zone. There are
|
||||
two trip points which can be set by user to get notifications via thermal
|
||||
notification methods.
|
||||
|
||||
config INTEL_SOC_DTS_THERMAL
|
||||
tristate "Intel SoCs DTS thermal driver"
|
||||
depends on X86 && IOSF_MBI
|
||||
help
|
||||
Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
|
||||
temperature sensor (DTS). These SoCs have two additional DTSs in
|
||||
addition to DTSs on CPU cores. Each DTS will be registered as a
|
||||
thermal zone. There are two trip points. One of the trip point can
|
||||
be set by user mode programs to get notifications via Linux thermal
|
||||
notification methods.The other trip is a critical trip point, which
|
||||
was set by the driver based on the TJ MAX temperature.
|
||||
|
||||
config INT340X_THERMAL
|
||||
tristate "ACPI INT340X thermal drivers"
|
||||
depends on X86 && ACPI
|
||||
select THERMAL_GOV_USER_SPACE
|
||||
select ACPI_THERMAL_REL
|
||||
select ACPI_FAN
|
||||
help
|
||||
Newer laptops and tablets that use ACPI may have thermal sensors and
|
||||
other devices with thermal control capabilities outside the core
|
||||
CPU/SOC, for thermal safety reasons.
|
||||
They are exposed for the OS to use via the INT3400 ACPI device object
|
||||
as the master, and INT3401~INT340B ACPI device objects as the slaves.
|
||||
Enable this to expose the temperature information and cooling ability
|
||||
from these objects to userspace via the normal thermal framework.
|
||||
This means that a wide range of applications and GUI widgets can show
|
||||
the information to the user or use this information for making
|
||||
decisions. For example, the Intel Thermal Daemon can use this
|
||||
information to allow the user to select his laptop to run without
|
||||
turning on the fans.
|
||||
|
||||
config ACPI_THERMAL_REL
|
||||
tristate
|
||||
depends on ACPI
|
||||
|
||||
config CPU_THERMAL_IPA
|
||||
bool "Enable Intelligent Power Arbiter"
|
||||
depends on THERMAL && CPU_FREQ && EXYNOS_THERMAL
|
||||
help
|
||||
This implements the Intelligent Power Arbiter (IPA)
|
||||
|
||||
config CPU_THERMAL_IPA_CONTROL
|
||||
bool "Enable control"
|
||||
depends on CPU_THERMAL_IPA
|
||||
help
|
||||
This implements the intelligent power arbiter (IPA) control algorithms.
|
||||
If you want this support, you should say Y here.
|
||||
|
||||
config CPU_THERMAL_IPA_DEBUG
|
||||
bool "Enable debugging"
|
||||
depends on CPU_THERMAL_IPA
|
||||
select FUNCTION_TRACER
|
||||
select DYNAMIC_FTRACE
|
||||
help
|
||||
This enables *trace* routines in IPA, used to collect logs
|
||||
of temperature, CPU and GPU utilisations and power
|
||||
estimates. If you want to analyze IPA behaviour, you should
|
||||
say Y here.
|
||||
|
||||
menu "Texas Instruments thermal drivers"
|
||||
source "drivers/thermal/ti-soc-thermal/Kconfig"
|
||||
endmenu
|
||||
|
||||
menu "Samsung thermal drivers"
|
||||
depends on ARCH_EXYNOS
|
||||
source "drivers/thermal/samsung/Kconfig"
|
||||
endmenu
|
||||
|
||||
menu "STMicroelectronics thermal drivers"
|
||||
depends on ARCH_STI && OF
|
||||
source "drivers/thermal/st/Kconfig"
|
||||
endmenu
|
||||
|
||||
endif
|
||||
|